Raisecom RC3000 PCM Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Netzwerkmedienkonverter Raisecom RC3000 PCM herunter. RC3000-15 Multi Service Access Node Relative Standards Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 9
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
RC3000-15 Multi Service Access Node
Tel: +86 10 8288 3305
Fax: +86 10 8288 3056
Email: info@raisecom.com
http://www.raisecom.com
@2006 Raisecom Technology, Co., Ltd
All trademarks are the property of their
respective owners.
Technical information is subject to change
without notice.
Raisecom Technology Co., Ltd.
Item RC3000-15 RC3000-6
Chassis(high)
6U 3U
Number of Service-slots
13 6
Number of Power-slots
2 2
Max. E1 channels
96 32
Cross-connect capactiy
256 Mbps 256 Mbps
Max. FXO/FXS channels
352 128
Max. E&M channels 192 64
Max. V.35 channels 96 32
Max. FE channels 96 32
Physical Description
Height 267mm(10.5 in.) 134mm(5.3 in.)
Width 483mm(19.0 in.) 483mm(19.0 in.)
Depth 240mm(9.42 in.) 240mm(9.42 in.)
Power supply
DC:- 48V
-36V~-72V
Power consumption ≤150W ≤80W
Ringing generator 75V; 25Hz
Operating Environment
Temperature -5° to 50° C
Air pressure 86 to 106Kpa
Humidty 5% to 95% relative humidity, noncondensing
ITU-T G.703 ITU-T G.704
ITU-T G.706 ITU-T G.707
ITU-T G.711 ITU-T G.712
ITU-T G.713 ITU-T G.714
ITU-T G.732 ITU-T G.813
ITU-T G.821 ITU-T G.823
ITU-T G.825 ITU-T G.826
ITU-T V.35 ITU-T V.11
ITU-T V.24 ITU-T V.28
Raisecoms RC3000-15 represents a new
generation of intelligent multi service
access concentrator designed for cost-
eective and ecient customer premises
multiplexer. It provides full range of voice
and digital data services to subscribers
located at dierent locations require to
interconnect and establish a voice and
data network over E1 and STM1 link.
The RC3000-15 Multi Service Access Node,
whose kernel is powerful cross matrix,
is integrated with the functions of digit/
analogue access multiplexer cross-connect
transmission and protocol conversion. The
RC3000-15 has capacity for 13 single slots
and 2 power supply slots. The RC3000-6
has capacity for 6 single slots and 2
power supply slots. The 19 inch 6U high
RC3000-15 and 3U high RC3000-6 provide
access for a variety of interfaces, including
STM-1, 1/4/8/16 optical E1, Electrical E1,
FXO, FXS, E&M, Analog voice trunk, Hot-
line, magneto telephone, RS232, RS422,
RS485, G.703, V24, V35, G.SHDSL , FE and
GE. These interfaces are compatible with
other Raisecoms products such as the
OPCOM3500E (SDH), the RC3000 (PCM),
the RC3101 (PCM), and the RC3201 (PCM).
By deploying these products, network is
integrated broadband and narrowband,
and transmission and access.
Raisecoms network management platform
NVIEW NNM is also available for gure
information of the real-time monitoring,
alarms, management and maintenance.
Relative Standards
Specication
Datasheet
Introduction:
RC3000-15 adopts rack design, including
chassis, fan board, plug board and power
supply board.
For the plug board, including following parts:
STM-1 board: STM-1 boards should be in slot 1
or 2.
System control board: DXC boards should be
in slot 7 or 8.
GE aggregate board: SUB-ESW-2GE boards
should be in slot 9.
Power supply board: Power boards should be
in slot 14 or 15.
Services board: E1, PDH ber, FXO, FXS,
Hot-
line,
2/4Wire E&M, RS232/V.24, RS485/V.28,
V.35(Nx64 Kbps), G.703, Ethernet LAN(Nx64
Kbps), inverse multiplexing, G.SHDSL boards
should be in slot 1,2,3,4,5,8,9,10,11,12,13.
RC3000-15
Multi Service Access Node
RC3000-6
Multi Service Access Node
Raisecom Technology Co., Ltd.
RM.217, 2nd Floor South Building of
Rainbow Plaza, No.11
Shangdi Information Road,
Haidian District, Beijing 100085
Seitenansicht 0
1 2 3 4 5 6 7 8 9

Inhaltsverzeichnis

Seite 1 - Datasheet

RC3000-15 Multi Service Access NodeTel: +86 10 8288 3305Fax: +86 10 8288 3056Email: [email protected]://www.raisecom.com@2006 Raisecom Technology,

Seite 2 - Feature

Raisecom Technology Co., Ltd.Tel: +86 10 8288 3305Fax: +86 10 8288 3056Email: [email protected]://www.raisecom.com@2006 Raisecom Technology, Co.,

Seite 3 - Main Technical Performance

Raisecom Technology Co., Ltd.Tel: +86 10 8288 3305Fax: +86 10 8288 3056Email: [email protected]://www.raisecom.com@2006 Raisecom Technology, Co.,

Seite 4

Raisecom Technology Co., Ltd.Tel: +86 10 8288 3305Fax: +86 10 8288 3056Email: [email protected]://www.raisecom.com@2006 Raisecom Technology, Co.,

Seite 5 - Typical Application

Raisecom Technology Co., Ltd.Raisecom Technology Co., Ltd.RM.217, 2nd Floor South Building of Rainbow Plaza, No.11Shangdi Information Road,Haidian Dis

Seite 6

Raisecom Technology Co., Ltd.Raisecom Technology Co., Ltd.RM.217, 2nd Floor South Building of Rainbow Plaza, No.11Shangdi Information Road,Haidian Dis

Seite 7 - Ordering Information

Raisecom Technology Co., Ltd.Tel: +86 10 8288 3305Fax: +86 10 8288 3056Email: [email protected]://www.raisecom.com@2006 Raisecom Technology, Co.,

Seite 8

Raisecom Technology Co., Ltd.Tel: +86 10 8288 3305Fax: +86 10 8288 3056Email: [email protected]://www.raisecom.com@2006 Raisecom Technology, Co.,

Seite 9

Raisecom Technology Co., Ltd.Tel: +86 10 8288 3305Fax: +86 10 8288 3056Email: [email protected]://www.raisecom.com@2006 Raisecom Technology, Co.,

Kommentare zu diesen Handbüchern

Keine Kommentare