Beijing Raisecom Science & Technology Co., Ltd
Figure 4-19 The Modify dialog box
The description of information available on this interface are listed as follows:
Object Description
COM Port Number The value of COM Port Number provided at present is from 1 to 16.
COM Port Status Supports two status, open and close.
Device Type The device type managed under current COM Port.
Port Bit/Second (Baud
Rate)
The default value is 19200. It may be varying depending on the
configuration of devices, see “Hardware User Manual” for details. The
port bit can be configured properly only when this COMM Port is in
close state, so it is required to keep the COMM Port in close when
configuring this item.
The buttons available on this interface are listed as follows:
Object Description
Save Click this button to accept modification and close this window.
Close
Click this button to cancel operations and close this window.。
Step 3. Firstly, configure device type and baud rate for the device managed by this COM Port.
Figure 4-20 The Modify dialog box
Note: The Port Bit can be configured successfully only when this COM Port is in close state. So it is
recommended you keep the COM Port in close as possible.
After you made modification to device type and port bit, click the [Save] button.
Step 4. After the successful save, change the COM Port Status to be Open, and click the [Save] button.
RC003COMM(RC004-16) EMS User Manual 29
Kommentare zu diesen Handbüchern